Category: | Pendulum impact testing machine |
---|---|
Brand: | WANCE |
Country: | China |
Impact energy:
150J, 300J, 450J
Functions:
This machine is used for measuring the Charpyimpact resistance of metal and other materials
Standards:
ISO 148, EN10045, ASTM E23, GB/T 229, GB/T 12778, GOST 9454
Features:
- One-body cast frame design of seat and column provide high stability and rigidity
- Front and rear columns are symmetrical. Pendulum arm is designed of cantilever beam support, with simple structure and high machined precision
- Apply high precision bearing with small friction. Absorbing energy without loading is less than 0.3%
- Double reduction gear system replaces old style drive system with high efficiency and avoiding transmission failure
- Round pendulum head design reduces windage losses to the most
- High rigid pendulum arm prevents axial and transverse vibrations
- Exchangeable pendulum is simple to change to satisfy impact energy of 150J, 300J, 450J
- Electromagnetic release of pendulum hammer and electromagnetic clutch for locking the pendulum and raising it to its initial position. A damper is equipped to prevent strong bump when clutching
- Full-closed enclosure with high safety to prevent broken sample from splitting. Protective screening has interlock door. When the door opens, most operations can’t work to avoid any wrong operation
- Apply SIEMENS industrial PLC to control pendulum, and high precision Japanese made NEMICON rotary encoder to measure striker real time position. The whole system is stable, reliable and accurate
- A big touch screen monitor may real-time displays striker angle, impact energy, toughness, and other parameters. User can input specimen data and other information such as company information into this monitor. When connected to a printer, user input information and test results will be printed
- Optional computer with software control is available to realize semiautomatic operation.
- Operator only need charge specimens. Others can be controlled by software
- Optional specimen feeding system is available. Combined with computer and software, fully automatic operation can be realized
- Optional cooling system is available to satisfy cold specimen test down to -180°C
Specimen collection and filtering device
- Motorized device is used for collecting broken specimens after impact, instead of manual cleaning, which fully prevents striker from getting stuck
- Unique specimen filtering function: automatically judge and transport qualified and unqualified specimens to different collecting box
Professional test software
This software is designed specifically for testing metals to Charpy standards. Software provides an easy-to-use method for gathering, calculating and storing impact test results. The test result can be printed and exported to EXCEL for review.
Display Features
- Status of system limits
- Real-time display of hammer status
- Hammer set up and verification allows for hammer weight input
- Displays potential/impact energy
- Displays theoretical velocity
- Encoder resolution of 0.025°